Műszaki paraméterek:
Battery Module | 10KWh | ||
---|---|---|---|
Combination method | 16 S | ||
Raated Capacity Typical | 200 Ah | ||
Raated Capacity Minimum | 200 Ah | ||
Factory Voltage | 49,5 - 50,5 V | ||
Voltage at end of Discharge | 40 - 42,5 V | ||
Charging Voltage | 53,2 - 54 V | ||
Internal Impedance | 50 Ohm | ||
Standard charge | Constant Current 20A Constant Voltage 0.01CA cut-off | ||
Standard discharge | Constant current: 20A end voltage | ||
Maximum Continuous Charge Current | 100A | ||
Maximum Continuous Discharge Current | 100A | ||
OperationTemperature Range | Charge: 0~45°C | ||
OperationTemperature Range | Discharge: -20~55°C | ||
Storage Temperature Range | Less than 12 months: -10~35°C | ||
Storage Temperature Range | Less than 3 months: -10~45°C | ||
Storage Temperature Range | Less than 7 day: -20~65°C | ||
Volumetric specific energy | 127WH/L | ||
Gravimetric specific energy | 109WH/KG | ||
Cycle life | 6000 Cycle | ||
Dimensions | 480*650*242 mm | ||
Weight | 88kg | ||
BMS Specification: | |||
The BMS is designed for 15/16 series lithium battery. | |||
The BMS have all functions which are : | Overcharge detection function Over discharge detection function Over current detection function Short detection function Temperature Temperature detection function Balance function Communicate function Alarm function | ||
48V 15S / 16S Typical value specifications : | |||
Items | Details | Standard | |
Cell overcharge protection | Overcharge detection voltage | 3.70±0.025V | |
Cell overcharge protection | Overcharge detection delay time | Typical:1.0s | |
Cell over-discharge protection | Overcharge release voltage | 3.45±0.02V | |
Cell over-discharge protection | Over-discharge detection voltage | 2.75±0.02V | |
Cell over-discharge protection | Over-discharge detection delay time | Typical:1.0s | |
Over-current protection | Over-discharge release voltage | 3.05±0.02V or charge release | |
Over-current protection | Discharge Over-current protection current1 | 120±10A | |
Over-current protection | Discharge Over-current detection delay time 1 | 1S | |
Over-current protection | Discharge Over-current protection current2 | 150±10A | |
Over-current protection | Discharge Over-current detection delay time2 | 3.45≤100ms±0.02V | |
Over-current protection | Charge OC protection current | 120±10A | |
Short protection | Short protection current | 350±10A | |
Short protection | Protection condition | Load short | |
Short protection | Detection delay time | ≤800us | |
Short protection | Protection release condition | Charging release | |
Temperature(T) protection | Charge high (T) protection | 65±2°C | |
Temperature(T) protection | Charge high (T) recover | 60±5°C | |
Temperature(T) protection | Discharge high (T) protection | 65±2°C | |
Temperature(T) protection | Discharge high (T) recover | 60±5°C | |
Temperature(T) protection | Charge low (T) protection | -5±2°C | |
Temperature(T) protection | Charge low (T) recover | 0±2°C | |
Temperature(T) protection | Discharge low (T) protection | -20±5°C | |
Temperature(T) protection | Discharge low (T) recover | -15±5°C | |
Balance | Balance threshold voltage | 3.45V | |
Communication | It has RS232 and RS485 standard communication interface, it can real-lime monitoring the capacity of battery bank, the voltage, current, environment temperature, and charging/discharging current. | ||
Alarm | It has over-temperature, over charge, under-voltage, over-current, short circuit alarm function |